Case Study
Preventing Motor Failures with Mechanical Thermography
This case study demonstrates how routine mechanical thermography identified abnormal overheating in a large DC motor before a major failure occurred. Thermal imaging revealed a significant temperature increase that led investigators to discover a blocked cooling air filter restricting airflow through the motor. Correcting the issue prevented damage to motor windings and bearings, improved equipment reliability, reduced operating costs, and extended asset life. The study highlights how mechanical thermography complements traditional condition monitoring by detecting hidden faults in rotating equipment before they become costly failures.